FREE SHIPPING for all orders over $40
The M5Stack CO2L Unit is a compact digital air quality unit for CO2 concentration, temperature, and humidity monitoring. It uses Sensirion’s SCD41 sensor, an integrated power step-down circuit, and an I2C interface, making it easy to add environmental sensing to M5Stack controllers and automation projects.
The CO2 temperature humidity sensor measures CO2 from 400 ppm to 5000 ppm with typical CO2 accuracy of +/-(40 ppm + 5% of reading). Low-power single measurement support makes the I2C CO2L environmental sensor useful for periodic air quality checks, indoor monitoring, and battery-conscious systems.
| Sensor | SCD41 |
| CO2 Range | 400 to 5000 ppm |
| CO2 Accuracy | +/-(40 ppm + 5% of reading) |
| Temperature Range | -10 to 60 degC |
| Humidity Range | 0 to 95 %RH |
| Communication Interface | I2C @0x62 |
| Connector | HY2.0 4P |
| Power Conversion | Integrated 5V to 3.3V LDO |
| Product Size | 48.0 x 24.0 x 16.0mm |
| Product Weight | 7.5g |
| Package Size | 138.0 x 93.0 x 17.0mm |
| Gross Weight | 12.8g |
| 1 | Unit CO2L |
| 1 | HY2.0 connecting cable (20CM) |
The Unit CO2L uses a single-shot measurement mode for lower power operation. This is helpful when a project only needs periodic CO2, temperature, and humidity readings instead of continuous measurement.
| Grove Pin | Signal |
| Black | GND |
| Red | 5V |
| Yellow | SDA |
| White | SCL |
Before installation, keep airflow around the sensor opening unobstructed and avoid placing the CO2 temperature humidity sensor next to direct heat sources, condensation, or strong drafts that could distort environmental readings.
It measures CO2 concentration, ambient temperature, and relative humidity through the SCD41 sensor.
The M5Stack CO2L Unit communicates through I2C at address 0x62.
Single measurement mode is useful for low-power projects that only need occasional air quality readings instead of continuous sampling.