An analog pH sensor measures the hydrogen-ion concentration in a liquid, outputting a continuous voltage signal that maps to a 014 pH scale. These modules consist of two primary parts: an electrochemical glass probe (with a BNC connector) and a signal conditioning amplifier board.Because the raw probe generates microscopic millivolt fluctuations with incredibly high internal impedance, the onboard amplifier stabilizes and scales the signal so standard microcontrollers like Arduino or ESP8266 can interpret it.Hardware & Interface PinoutMost hobbyist and industrial analog pH modulesuse a standard interface:
How It Works (The Science)
Arduino WiringWiring Diagram
| Sensor Board Pin | Arduino Pin |
|---|---|
| VCC | 5V |
| GND | GND |
| PO | A0 |
Conversion LogicThe relationship between the output voltage and the pH scale is strictly linear. The mathematical model utilizes a defined step-slope (0.18V per pH unit change) combined with an offset variable:pH = 7.0 + ((2.5 – V_out) / Slope)Essential Calibration ProcedureAnalog pH probes drift over time due to temperature changes and glass aging. You must calibrate them before your first reading: