“A dependable industrial and commercial choice for high-amperage feeder systems, branch circuits, and secondary sub-panel installations. Engineered with a lightweight, interlocking aluminum armor jacket, this pre-protected 3-conductor plus ground assembly eliminates the extensive material and labor expenses of traditional conduit piping. It allows electrical crews to route heavy service lines directly through walls, ceilings, and open cable trays in a fraction of the time.”
4/0 3-Conductor Aluminum Metal Clad (MC) Cable delivers a completely code-compliant, pre-armored wiring solution designed to minimize field labor hours and maximize jobsite efficiency. Featuring three compact-stranded AA-8000 series aluminum phase conductors insulated with cross-linked polyethylene (XLPE/XHHW-2) and a dedicated bare grounding wire, the assembly is protected by an overall interlocking aluminum armor jacket.
Labor-Saving Armor: The integrated aluminum interlocked armor serves as its own flexible metallic protective raceway, removing the tedious labor of bending and installing separate EMT or rigid conduit systems.
AA-8000 Conductor Material: Manufactured with compact-stranded 8000-series aluminum alloy to ensure high electrical conductivity, dramatically reduced weight strain during long structural pulls, and excellent flexibility.
XHHW-2 Insulation: Individual phase conductors are insulated with cross-linked polyethylene (XLPE), providing elite resistance to heat, moisture, and electrical stress in challenging industrial environments.
Maximum Versatility: Code-approved for an exceptionally broad range of heavy-duty installations including commercial distribution panels, large equipment feeders, vertical risers, and environmental air-handling spaces (plenums).
Cut to Length or Bulk Spools: Order custom cut-to-length footage to eliminate jobsite waste, or select full factory spools and reels for major commercial installation pulls.
Conductor Configuration: 3 Insulated Conductors + 1 Bare Ground Wire
Conductor Size: 4/0 AWG
Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy (per ASTM B800 & B801)
Conductor Colors (240V): Black, White, Red
Ground Wire Size: 2 AWG (Bare Stranded Aluminum)
Insulation: High-Heat & Moisture Resistant Cross-Linked Polyethylene (XLPE / Type XHHW-2). A binder tape is wrapped over the insulated conductors’ assembly.
Armor: Overall Aluminum Interlocked Armor
Voltage Rating: 600 Volts
Temperature Rating: -40C to 90C
Amp Rating (@ 75C – NEC): 180 Amps
Amp Rating (@ 90C – NEC): 205 Amps
Insulation Thickness: 0.055 inches
Diameter Over Armor: 1.64 inches
Net Weight: 1,038 lbs per 1,000 ft
Minimum Bending Radius: 11.48 inches (Calculated as 7x Diameter Over Armor)
Compliance Standards: UL 44, UL 1569 for Type MC Cable (CT Use Rated), NEMA WC-70/ICEA S-95-658, IEEE 1202 70,000 BTU/HR Vertical Tray Flame Test, ASTM B800 & B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces (plenums).
175A200A Sub-Panel Feeds: Primary 3-phase feeder lines running from main distribution switchboards to 175A or 200A sub-panels in office complexes, retail centers, and industrial facilities.
Heavy HVAC & Industrial Equipment: Dedicated power feeds for 3-phase commercial rooftop HVAC units (RTUs), chillers, industrial air compressors, and heavy machinery not requiring a neutral conductor.
Open Plenum & Drop-Ceiling Routing: Fully certified under NEC 300.22 for routing directly through environmental air-handling plenum spaces, dropped ceiling voids, and raised floors without conduit.
Commercial EV Charging & Transformers: Reliable power distribution for high-output commercial EV charging hubs, step-down transformers, and large battery backup systems.
Multi-Story Vertical Shafts: Approved for vertical riser shafts in commercial structures and high-rise facilities when secured per NEC 300.19 and 330.30 guidelines.
Technical Note:All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyers responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. Reference NEC Article 330 for specific Metal-Clad installation guidelines.
Ampacity Note: Values calculated based on National Electrical Code (NEC) standards. Because most standard commercial electrical panels, breakers, and terminal lugs feature 75C termination points, circuits are typically designed based on the conservative 180-Amp standard. The 205-Amp rating at 90C is highly utilized for ampacity adjustment and correction factors.