FREE SHIPPING for all orders over $40
This 10 AWG, 12-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding multi-circuit supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20/10 PE/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.
Heavy-Duty 20/10 Composite Insulation: Each of the 12 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.
Superior EMI/RFI Shielding: Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic/electrostatic currents caused by breaker operations and inductive switching.
Utility-Grade Durability: Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation pathsapproved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.
Corrosion-Resistant Base: Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.
Substation Control Networks: Consolidating multiple digital or analog signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.
Protective Relaying & Telemetry: Connecting arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.
Utility Metering & Monitoring: Long-run multi-point data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.
Industrial Heavy Duty Control: General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.
Conductor Size: 10 AWG
Number of Conductors: 12
Conductor Material: Bare Soft Annealed Copper (Class B Stranded)
Insulation System: 20 mils PE / 10 mils PVC (Total 30 mils per conductor)
Shielding: 0.005″ (5 mil) Helical Bare Copper Tape Shield
Jacket: Flame-Retardant, Moisture- & Sunlight-Resistant Black PVC
Voltage Rating: 600V (Available up to 1000V for heavy inductive breaking profiles)
Temperature Rating: 75C Wet or Dry
Compliance Standards: ICEA S-73-532 / NEMA WC 57, ASTM B3 & B8, RoHS Compliant
Technical Note: Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. Verify grounding specs against the specific utility engineering layout.
CABLE TYPE: 10 AWG / 12-Conductor Shielded Substation Control Cable
DISCLAIMER: The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.
Only logged in customers who have purchased this product may leave a review.