“Engineered for budget-friendly power distribution and smooth conduit pulls, 8 AWG Aluminum XHHW-2 / RW90 Building Wire features compact-stranded AA-8000 aluminum alloy wrapped in a slick, low-friction XLPE jacket. Dual-rated for 600V/1000V systems and approved for wet or dry locations up to 90C, it delivers superior cost and weight savings over copper for feeder runs, branch circuits, subpanels, and raceway applications.”
Slick, Low-Friction XLPE Insulation: Features an advanced “slippery” outer compound that glides through conduit bends effortlessly without pulling lubricant or insulation damage.
AA-8000 Series Compact Aluminum: Built with Class B compact-stranded AA-8000 series aluminum alloy, reducing wire diameter to maximize conduit fill capacity.
Dual Voltage Rated (600V / 1000V): Rated for standard 600V systems as well as higher-voltage 1000V commercial and solar installations.
Phase Color Selection: Offered in Black, Red, White, Green, Blue, Orange, Brown, Yellow, Gray, and Purple for instant phase identification (check the dropdown above for real-time stock).
Cut-to-Length or Bulk Spools: Order custom lengths cut by the foot to minimize job-site scrap, or purchase bulk spools for high-volume commercial runs.
Conductor Size: 8 AWG
Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy (Class B)
Conductor Diameter: 0.134 inches (3.40 mm)
Insulation Material: Cross-Linked Polyethylene (XLPE / XLP)
Insulation Thickness: 0.045 inches (1.14 mm)
Overall Diameter: 0.227 inches (5.77 mm)
Approximate Net Weight: 30 lbs per 1,000 ft
Ampacity (@ 75C Terminal Rating): 40 Amps
Ampacity (@ 90C Terminal Rating): 45 Amps
Voltage Rating: 600V / 1000V (XHHW-2) | 600V (RW90)
Temperature Rating: -40C to 90C (Wet or Dry)
Compliance Standards: UL 44 / CSA C22.2 No. 38, UL 1685, ANSI/NEMA WC-70 / ICEA S-95-658, ASTM B800 & B801, Federal Spec A-A-59544A, NFPA 70 (NEC), CSA C22.1.
Service Entrances & Feeders: Routing branch circuits and subpanel feeds through underground or indoor conduit systems.
Commercial & Residential Raceways: Pulling through electrical metallic tubing (EMT), PVC conduit, or flexible raceways for HVAC, motors, and machinery.
Outdoor & Wet Location Wiring: Ideal for installations exposed to moisture, changing temperatures, or direct sunlight inside approved raceways.
DISCLAIMER: All values are nominal and subject to correction. Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30C per Table 310.16 of the National Electrical Code.