The Analog to I2C Unit 4-20mA Input, also documented as Unit AIN4-20mA, is a single-channel 4-20mA current analog measurement unit for M5Stack systems. It uses an STM32G030F6 controller and communicates with the host through I2C, so a controller can read industrial current sensor data without handling raw analog conversion directly.
The 4-20mA I2C measurement unit supports both 2-wire and 4-wire sensor wiring through jumper cap configuration. Its onboard power isolation chip and op-amp circuit help the isolated current sensor unit measure external current sensors accurately while improving signal integrity and system safety.
| MCU | STM32G030F6P6 |
| Signal Isolation Chip | HCNR200 |
| Op-Amp Chip | SGM321YC5/TR |
| Communication Interface | I2C @0x55 |
| Input Impedance | IN+ and IN- typical value 200 Ohm |
| Operating Temperature | 0 to 40 degC |
| Product Size | 56.0 x 24.0 x 11.3mm |
| Product Weight | 8.8g |
| Package Size | 138.0 x 93.0 x 12.3mm |
| Gross Weight | 17.1g |
| 1 | Unit AIN4-20mA |
| 1 | HT3.96-4P Terminal |
| 1 | HY2.0-4P Grove Cable (20 cm) |
| 3 | Jumper Cap |
Jumper caps select the wiring mode of the 4-20mA I2C measurement unit. For a passive current-type sensor, connect the DC 24V power supply input, connect the sensor signal to IN+ and IN-, and set the jumper caps to the passive wiring position. For an active current-type sensor, connect the sensor signal to IN+ and IN- and set the jumper caps to the active wiring position.
| Wiring Mode | Connection Guidance |
| Passive current sensor | Use DC 24V supply input and connect sensor signal to IN+ / IN- |
| Active current sensor | Connect sensor signal to IN+ / IN- and use the active jumper position |
| Grove Pin | Signal |
| Black | GND |
| Red | 5V |
| Yellow | SDA |
| White | SCL |
Before commissioning the isolated current sensor unit, confirm the sensor type, jumper position, and power wiring. A known current source or calibrated transmitter is recommended for checking the Unit AIN4-20mA reading range.
It measures a single-channel 4-20mA current signal and makes the reading available to the host through I2C.
Yes. The Analog to I2C Unit 4-20mA Input supports both wiring types through jumper cap configuration.
Confirm the sensor wiring, jumper cap position, and power supply mode before relying on the 4-20mA I2C measurement unit in an automation system.