FREE SHIPPING for all orders over $40

Searching

6/2 Unshielded Substation Control Cable - 20/10 PE/PVC

6/2 Unshielded Substation Control Cable - 20/10 PE/PVC

$1,082.00 $145.00
This 6 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable…

This 6 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20/10 PE/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.

Key Features of 6/2 Unshielded 20/10 Substation Cable

  • Heavy-Duty 20/10 Composite Insulation: Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.

  • Unshielded Optimization: Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.

  • Utility-Grade Durability: Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.

  • High-Ampacity Conductor Base: Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.

Common Applications

  • Substation DC Distribution: Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.

  • Station Service Power: Providing reliable auxiliary AC/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.

  • Heavy Control Circuits: Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.

  • Industrial Power Distribution: General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.

Conductor Identification: ICEA E-1 Color Code Sequence

  • 1: Black

  • 2: White

Technical Specifications

  • Conductor Size: 6 AWG

  • Number of Conductors: 2

  • Conductor Material: Bare Soft Annealed Copper (Class B Stranded)

  • Insulation System: 20 mils PE / 10 mils PVC (Total 30 mils per conductor)

  • Shielding: None (Unshielded)

  • Jacket: Flame-Retardant, Moisture- & Sunlight-Resistant Black PVC

  • Voltage Rating: 600V

  • Temperature Rating: 75C Wet or Dry

  • Compliance Standards: ICEA S-73-532 / NEMA WC 57, ASTM B3 & B8, RoHS Compliant

Technical Note: Since this cable is unshielded, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable’s routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.

CABLE TYPE: 6 AWG / 2-Conductor Unshielded Substation Control Cable

DISCLAIMER: The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.

Only logged in customers who have purchased this product may leave a review.